## When univariate charts are not enough

Suppose you are running a chemical reactor with three process
variables — *temperature*, *pressure*, *flow* — that are mechanically
coupled. In normal operation they move together: when temperature
rises, pressure rises with it. A failure that **breaks the coupling**
(say, a stuck pressure sensor that reads near the mean while
temperature drifts) leaves the marginal distribution of each
variable inside its 3-sigma limits, but the *joint* distribution is
clearly not what it was. Three Shewhart I charts would tell you
nothing has happened.

This is the textbook case for a multivariate chart: when the
informative signal lives in the correlation structure, not in any
one marginal.

```{r}
# Correlated baseline — temperature and pressure track together
set.seed(2026)
n     <- 80
Sigma <- matrix(c(1, 0.92, 0.92, 1), 2, 2)
Z     <- MASS::mvrnorm(n, mu = c(0, 0), Sigma = Sigma)

# A "stuck pressure" fault: temperature still varies, pressure stays put
faulty <- cbind(temp = rnorm(20, 0, 1), pressure = rnorm(20, 0, 0.05))

reactor <- tibble::tibble(
  hour     = 1:100,
  temp     = c(Z[, 1], faulty[, 1]),
  pressure = c(Z[, 2], faulty[, 2])
)
```

A glance at each variable independently shows nothing dramatic:

```{r}
shewhart_i_mr(reactor, value = temp,     index = hour) |> autoplot()
shewhart_i_mr(reactor, value = pressure, index = hour) |> autoplot()
```

But the Hotelling chart catches the fault:

```{r}
fit <- shewhart_hotelling(reactor, vars = c(temp, pressure),
                          index = hour)
fit
autoplot(fit)
```

## What the chart computes

The Hotelling `T²` statistic is the squared Mahalanobis distance of
each observation from the joint mean, scaled by the inverse
covariance:

$$T^2_i = (x_i - \bar x)^\top S^{-1} (x_i - \bar x)$$

It collapses the `p`-variate problem to a single scalar, with a UCL
chosen so that under the null (process in control, multivariate
normal) the false-alarm rate per observation is `alpha`. The default
`alpha = 0.0027` matches the conventional Shewhart 3-sigma rate.

Two flavours, picked automatically by the constructor:

* **Individual observations** (`subgroup = NULL`, the default). Each
  row is one observation. Sigma is estimated from the row vectors.
* **Subgrouped observations** (`subgroup = column`). Rows sharing a
  value of `subgroup` form one subgroup, and `T²` is computed on the
  subgroup means with the pooled within-subgroup covariance.

For each flavour, the Phase I limit (retrospective evaluation of the
in-control assumption) and Phase II limit (prospective monitoring of
new data against the calibration) come from different exact
distributions; pass `phase = "phase_2"` for the wider Phase II UCL.

## Diagnosing an alarm with contributions

`shewhart_hotelling()` augments the output with a contribution
column per variable: the marginal increase in `T²` attributable to
that variable. When the chart fires, the contribution columns point
at the responsible variable(s).

```{r}
fit$augmented |>
  filter(.flag_signal) |>
  select(hour, .t2, .upper, starts_with(".contrib_")) |>
  head(5)
```

In our reactor example, observations after hour 80 typically have
the bulk of their `T²` value coming from `.contrib_pressure` — the
chart is correctly fingerprinting the stuck pressure sensor as the
culprit.

## Phase II workflow

The same `calibrate()` / `monitor()` workflow used for univariate
charts works for the multivariate chart too:

```{r}
set.seed(7)
in_control <- as.data.frame(MASS::mvrnorm(120, c(0, 0), Sigma))
names(in_control) <- c("temp", "pressure")
calib <- calibrate(in_control, vars = c(temp, pressure),
                   chart = "hotelling")

# Fresh data — pressure-sensor fault for the last 10 readings
new_data <- as.data.frame(MASS::mvrnorm(40, c(0, 0), Sigma))
names(new_data) <- c("temp", "pressure")
new_data$pressure[31:40] <- rnorm(10, 0, 0.05)

mon <- monitor(new_data, calib)
sum(mon$augmented$.flag_signal)
autoplot(mon)
```

`monitor()` reuses the Phase I mean vector and inverse covariance
(stored on the calibration object) and applies the appropriate Phase
II UCL — strict separation of estimation and monitoring, matching the
rest of the package's Phase I / Phase II story.

## When *not* to reach for a Hotelling chart

A multivariate chart **is not** a free upgrade over univariate
charts. Three reasons it is sometimes the wrong tool:

1. **Diagnosis is harder.** Univariate charts immediately tell you
   which variable drifted; the Hotelling chart needs the
   contribution decomposition to point at a culprit. For shifts that
   *only* affect one variable, the matched univariate chart usually
   has lower ARL_1.
2. **Sample-size hunger.** Estimating a `p × p` covariance well
   needs roughly `5 p` to `10 p` observations per chart parameter.
   For p = 5 variables that is ~50 observations just to characterise
   the in-control state. With sparse data, a multivariate chart is a
   noise generator.
3. **Model assumptions.** The exact UCL is calibrated under joint
   normality. Multivariate non-normality, especially heavy tails,
   inflates the false-alarm rate. Check
   `shewhart_diagnostics()` per variable before committing.

A common production pattern: run univariate Shewhart or EWMA charts
on every variable for direct diagnosis, **and** a Hotelling chart on
top to catch the correlation-breaking faults the univariate charts
will miss.

## References

* Hotelling, H. (1947). Multivariate quality control. In:
  *Techniques of Statistical Analysis*. McGraw-Hill.
* Tracy, N. D., Young, J. C., & Mason, R. L. (1992). Multivariate
  control charts for individual observations. *Journal of Quality
  Technology*, 24(2), 88-95.
* Mason, R. L., Tracy, N. D., & Young, J. C. (1995). Decomposition
  of `T²` for multivariate control chart interpretation. *Journal of
  Quality Technology*, 27(2), 99-108.
* Mason, R. L., & Young, J. C. (2002). *Multivariate Statistical
  Process Control with Industrial Applications*. SIAM/ASA.
* Montgomery, D. C. (2019). *Introduction to Statistical Quality
  Control* (8th ed.). Wiley. Chapter 11.